TP1-IR-PH COMBO Touch Probe – assembly
Wireless

TP1-IR-PH COMBO Touch Probe

Wireless probe with CS16 and stylus, receiver cable in a flexible conduit

€1145
Documentation

Key Specifications

Measuring principle
Kinematic 3-point seating
Repeatability (stylus L30 mm)
0.005 mm
Measuring direction
±X, ±Y, -Z
Measuring force XY / Z (stylus L30 mm)
2 N / 6 N
Maximum deflection XY / Z
±10° / 4.5 mm
Maximum measuring speed
2 m/min

Description

The TP1-IR wireless touch probe is used for precise workpiece setup and tool measurement on CNC machine tools or as a precision limit switch in automation. Signal transmission between the probe and receiver is via infrared light. On the PH version the receiver cable is protected by a flexible conduit. The COMBO set adds the CS16 clamping shank and an M4 D3×20 ruby stylus to the probe, delivered as a pre-centered assembly ready to install in the machine spindle without further adjustment.

Package Contents

  • 1× TP1-IR touch probe (transmitter)

    Kinematic 3-point seating, 0.005 mm repeatability, IP65

  • 1× TP1-IR-PH receiver with bracket

    5 m cable protected by a flexible conduit, 4 × 0.25 mm², Touch and Ready output signals

  • 1× SAFT LS14250 battery

    Lithium 3.6 V / 1.2 Ah, ≈ 800 days in standby

  • 1× CS16 clamping shank

    For mounting the probe in the machine spindle, with four M6 centering screws in the collar

  • 1× M4 D3×20 Ruby Stylus

    Ø3 mm ruby ball, 20 mm length, M4 thread

  • 1× Adjustment tool set

    For centering the stylus and adjusting the probe

The BP58 base plate, for mounting the probe on the machine table, is ordered separately.

Wiring

Signal state
Signal type
Output signal
SW 1 Down, SW 2 Down, SW 3 Up1Down2Down3Up
Wire marking
TP1-IRwhiteGNDbrownVCCyellowTOUCHgreenREADY

Set on the switch on the receiver’s board, where the legend is printed too.

Output signal timing

051015t (ms)touchreadystylus
Timeline of the Touch and Ready outputs against the deflection of the stylus.

Operating Settings

The probe has two modes: standby and operating. Deflecting the stylus wakes it into operating mode and activates READY; after a set idle time it returns to standby.

P1

Duty cycle of the IR LED

Radiated power, set to the distance from the receiver. A higher duty cycle shortens battery life; the quoted range and battery figures are for the factory value.

  • 10 %P1 = 1
  • 20 %FactoryP1 = 2
  • 30 %P1 = 3
  • 40 %P1 = 4
  • 50 %P1 = 5
P2

Transition to standby

Idle time from the last deflection before the probe sleeps. In standby it does not transmit and READY is inactive.

  • 1 minFactoryP2 = 1
  • 2 minP2 = 2
  • 10 minP2 = 3
  • 20 minP2 = 4