# TP1-IR-PH Touch Probe

> Wireless touch probe, receiver cable protected by a flexible conduit

- **Product ID (SKU):** tp1-ir-ph
- **Manufacturer:** DynamiTech s.r.o., Prague, Czech Republic (EU)
- **Price:** $1270
- **Availability:** Normally in stock, shipped from the Czech Republic (EU)
- **Product page:** https://dynamitech.cz/product/tp1-ir-ph
- **Documentation:** https://docs.dynamitech.cz/tp1-family/
- **User manual (PDF):** https://dynamitech.cz/manuals/tp1-ir-user-manual.pdf

## Description

The TP1-IR wireless touch probe is used for precise workpiece setup and tool measurement on CNC machine tools or as a precision limit switch in automation. Signal transmission between the probe and receiver is via infrared light. The probe can be fitted with any touch stylus with M4 thread. To install the TP1 touch probe in the machine spindle (use as a workpiece probe), the CS16 clamping shank must be purchased separately — it allows precise centering of the stylus while the spindle rotates. For mounting the TP1 touch probe on the machine table (use as a tool probe), the BP58 base plate is available. When purchasing the TP1 touch probe together with the CS16 clamping shank, BP58 base plate and any touch stylus, you will receive a complete pre-centered assembly ready for immediate installation without further adjustment.

On the PH version the receiver cable is protected by a flexible conduit.

| Currency | Price |
| --- | --- |
| USD ($) | $1270 |
| EUR (€) | €1095 |
| CZK (Kč) | 26 900 Kč |

## Technical Specifications

### Product classification

| Parameter | Value |
| --- | --- |
| Product family | TP1 |
| Product type | Touch Probe |
| Connection | Wireless |
| Cable | None |
| Cable protection | Receiver cable in a flexible conduit |

### TP1-IR (Transmitter – Touch Probe)

| Parameter | Value |
| --- | --- |
| Measuring principle | Kinematic 3-point seating |
| Measuring direction | ±X, ±Y, -Z |
| Measuring force XY / Z (stylus L30 mm) | 2 N / 6 N |
| Maximum deflection XY / Z | ±10° / 4.5 mm |
| Repeatability (stylus L30 mm) | < 0.002 mm |
| Maximum measuring speed | 2 m/min |
| Weight | 260 g |
| Protection rating | IP65 |
| IR communication type | 950 nm |
| Maximum range (conditions dependent) | 5 m |
| Supply voltage SAFT LS 14250 | 3.6 V / 1.2 Ah |
| Battery life in standby | ≈ 800 days |
| Battery life in operating mode | ≈ 150 h |
| Storage temperature | -20 to +70 °C |
| Operating temperature | +10 to +40 °C |

### TP1-IR (Receiver)

| Parameter | Value |
| --- | --- |
| Supply voltage VCC | 5 – 24 VDC |
| Power consumption | < 100 mA |
| Maximum output current | 200 mA |
| Cable length | 8 m |
| Connection cable | 5 x 0.25 mm² |
| Weight | 135 g |
| Storage temperature | -20 to +70 °C |
| Operating temperature | +10 to +40 °C |
| Output signals | Touch, Ready, Battery low |
| Output signal type | PNP |

## Package Contents

- 1× TP1-IR touch probe (transmitter) — Kinematic 3-point seating, < 0.002 mm repeatability, IP65
- 1× TP1-IR-PH receiver with bracket — 8 m cable, the first 1 m protected by a flexible conduit, 5 × 0.25 mm², Touch, Ready and Battery low outputs (PNP)
- 1× SAFT LS14250 battery — Lithium 3.6 V / 1.2 Ah, ≈ 800 days in standby
- 1× Adjustment tool set — For centering the stylus and adjusting the probe

An M4 stylus, the CS16 clamping shank and the BP58 base plate are ordered separately.

## Wiring

### Wire marking

| Signal | Conductor colour | DIP switch |
| --- | --- | --- |
| GND | white | — |
| VCC | brown | — |
| READY | green | DIP 1 |
| TOUCH | yellow | DIP 2 |
| BATTERY-LOW | gray | DIP 3 |

### Output signal

Signal type: PNP

Set on the DIP switches on the receiver’s board, under the front glass cover, with the power off. The receiver reads them when it is powered up.

| Output | NO | NC |
| --- | --- | --- |
| Ready | DIP 1 OFF | DIP 1 ON |
| Touch | DIP 2 OFF | DIP 2 ON |
| Battery low | DIP 3 OFF | DIP 3 ON |

### Output signal timing

Timeline of the Touch and Ready outputs against the deflection of the stylus.

| Signal | 0 – 6 ms | 0 – 30 ms | 0 – 4 ms | 0 – 30 ms |
| --- | --- | --- | --- | --- |
| touch | ↑ 5 | ↓ 10 | ↑ 2 | ↓ 10 |
| ready | ↑ 5 |  |  |  |
| stylus | ↑ 2 | ↓ 0 | ↑ 0 | ↓ 0 |

Edges — ↑ rising, ↓ falling — in ms from the start of each stretch of the time axis; the axis restarts at 0 after each break.

| Stylus transition | Probe status | Touch delay | Ready delay | Battery low delay |
| --- | --- | --- | --- | --- |
| off → on | Standby | 3 ms | 3 ms | < 70 ms |
| off → on | Operating | 2 ms | — | — |
| on → off | Operating | 10 ms | — | — |

For accurate measurement on a CNC machine, keep the probe in Ready mode.

## Operating Settings

The probe has two modes: standby and operating. A touch, a spin or a change of position wakes it into operating mode — whichever P3 allows — and activates READY; after a set time from the last deflection it returns to standby. P1 to P3 are set; P4 is read-only.

### P1 — IR LED power

The radiated power, set to local conditions and the distance from the receiver. Higher power draws more in operating mode and shortens battery life; the quoted range and battery figures are for the factory value.

| Value | Parameter |
| --- | --- |
| 20 % | P1 = 1 |
| 40 % (Factory) | P1 = 2 |
| 60 % | P1 = 3 |
| 80 % | P1 = 4 |
| 100 % | P1 = 5 |

### P2 — Transition to standby

Time from the last deflection of the stylus before the probe sleeps. In standby it does not transmit and READY is inactive.

| Value | Parameter |
| --- | --- |
| 1 min (Factory) | P2 = 1 |
| 2 min | P2 = 2 |
| 5 min | P2 = 3 |
| 10 min | P2 = 4 |
| 20 min | P2 = 5 |

### P3 — Wake-up

What wakes the probe from standby into operating mode. A spin or a change of position has to last 2 s.

| Value | Parameter |
| --- | --- |
| By touch (Factory) | P3 = 1 |
| Spinning up to ≈ 520 rpm | P3 = 2 |
| Touch, or spinning up to ≈ 520 rpm | P3 = 3 |
| Spinning at ≈ 240 rpm, or turning by ≈ 50° | P3 = 4 |
| Touch, spinning at ≈ 240 rpm, or turning by ≈ 50° | P3 = 5 |

### P4 — Touches made

Read-only. The probe shows it by flashing the LED: the number of flashes is the number of touches in tens of thousands.

### Programming procedure

1. Remove the battery. Tilt the stylus and hold it.
2. Still holding it, insert the battery and screw on the cap. Green LED on.
3. After 2 s, green goes out and red comes on.
4. Release the stylus. Green for 1 s, then off — ready for P1.
   > If green flashes instead, programming mode was not entered — start again.
5. Deflect the stylus once per unit of P1, each touch under 0.5 s. Red follows the stylus.
6. Hold for over 1 s to confirm. With no short touch first, P1 is unchanged.
7. Green flashes back the value of P1.
8. Green for 1 s, then off — ready for P2. Repeat from step 5 for P2, P3 and P4.

## Images

- [TP1-IR-PH Touch Probe – Wireless touch probe, receiver cable protected by a flexible conduit](https://dynamitech.cz/sources/tp1-ir-ph-set.webp)
- [TP1-IR-PH Touch Probe – Wireless touch probe, receiver cable protected by a flexible conduit](https://dynamitech.cz/sources/tp1-ir-ph-set-2.webp)
- [TP1-IR-PH Touch Probe – transmitter dimension drawing](https://dynamitech.cz/sources/tp1-ir-transmitter-dimension.webp)
- [TP1-IR-PH Touch Probe – receiver dimension drawing](https://dynamitech.cz/sources/tp1-ir-ph-receiver-dimension.webp)

## Ordering

Order online at https://dynamitech.cz/cart or by email at info@dynamitech.cz. Prices are shown in US dollars; you can switch to EUR or CZK in the header or in the cart. VAT is added where applicable. Payment is by credit or debit card, or by bank transfer. We ship within the Czech Republic, across the EU, and internationally.